LIVSANE Pregnancy Test 1 Piece Rapid Self-Diagnostic Test
LIVSANE Pregnancy Test 1 Piece Rapid Self-Diagnostic Test
Description
LIVSANE PREGNANCY TEST Description The HCG pregnancy test is a self-diagnostic immunoassay designed for the rapid, visual, and qualitative detection of human chorionic gonadotropin (HCG) in urine samples to be used as an aid in the early diagnosis of pregnancy. Chromatographic immunoassay for the rapid qualitative detection of HCG in urine. The membrane is pre-coated with anti-alpha HCG capture antibodies in the test line area and goat anti-mouse antibodies in the control line area. During the test, the urine sample reacts with the colored conjugate (colloidal gold conjugate and mouse monoclonal anti-beta HCG antibodies) pre-dried on the test kit. The mixture then migrates upward along the membrane by capillary action reacting chromatographically with the colored conjugate. Positive samples react with the specific anti-HCG antibody colored conjugate forming a pink line in the test line area of the membrane. If no pink line appears in this area, the test result is negative. Regardless of the presence of HCG, as the mixture continues to migrate along the membrane towards the immobilized goat anti-mouse antibody, a pink line will always appear in the control line area. The presence of this pink line serves to: 1. verify that the added volume is sufficient; 2. confirm that the obtained flow is adequate; 3. act as a reagent control. Instructions for Use SAMPLE COLLECTION 1. Collect a fresh urine sample using a clean, dry, single-use container. 2. First morning urine samples generally contain the highest concentration of HCG for early pregnancy diagnosis. However, any urine sample can be used for the test. 3. Samples can be stored at room temperature for eight hours. If the test cannot be performed immediately, samples can be stored at 2-8 °C for 48 hours or at -20 °C for a maximum of 18 months. Do not freeze and thaw the sample more than once. 4. Bring the urine sample to room temperature before performing the test. TEST PROCEDURE Before performing the test, allow the kit, urine sample, and/or control devices to stabilize at room temperature (1-30 °C). Do not open the package until ready to perform the test. First morning urine samples generally contain the highest concentration of HCG for early pregnancy diagnosis. However, any urine sample can be used for the test. 1. Remove the kit from the sealed package and use it as soon as possible. 2. Remove the cap to expose the absorbent tip. 3. Hold the test by the handle with the absorbent tip facing downward. Urinate directly onto the absorbent tip until it is completely wet (at least 5 seconds). Alternatively, collect a urine sample in a clean, dry container with enough urine to fully immerse the absorbent tip for at least 5 seconds. NOTE: Be careful not to urinate on the result window. 4. Replace the cap and place the stick on a flat surface with the reading window facing upward. 5. Wait for the pink lines to appear. Read the result within 5 minutes. Do not read the result after 5 minutes. Interpretation of Results POSITIVE (PREGNANT): Two distinct pink lines appear, one in the test area (T) and one in the control area (C). NOTE: The intensity of the pink color in the test area (T) may vary depending on the concentration of HCG in the sample. Therefore, any shade of pink in the test region (T) should be considered a positive result. NEGATIVE (NOT PREGNANT): Only one pink line appears in the control area (C). No visible pink line appears in the test area (T). INVALID: The control line does not appear. NOTE: Insufficient sample volume or incorrect test execution are the most likely causes of the absence of the control line. Review the procedure and repeat the test with a new kit. If the problem persists, contact your local distributor. Warnings - Read the instructions carefully before performing the test. - Pay attention to the position of the C and T lines. - Do not use the product beyond the expiration date indicated on the label. - The test kit must be stored inside the sealed package until use. Do not use the product if the package is damaged or opened. - Do not reuse the test kit. Dispose of the product after a single use. - Do not touch the membrane inside the reading windows. - Do not ingest the desiccant. Limitations • Although it is not necessary to perform the test with first morning urine samples, excessive fluid intake before the test should be avoided. Overly diluted urine may give a false negative result. • The contents of this kit are intended exclusively for the qualitative detection of HCG in urine. • A sample with a low HCG level may show color changes over time. If pregnancy is suspected despite a negative result, collect another sample and repeat the test after 48-72 hours. • Fertility drugs containing HCG may produce misleading results (these drugs are usually administered by injection and testing too soon after administration may yield false positive results). • Other fertility treatments, painkillers, and hormonal contraceptives should not affect the result. • HCG may continue to be detectable for varying periods from several days to weeks after childbirth, miscarriage, or HCG injections. • Ectopic pregnancies, ovarian cysts, menopause, and some very rare diseases may cause erroneous results. • Although pregnancy is the most likely cause of HCG in serum and urine, elevated HCG concentrations not associated with pregnancy have been reported in some patients with trophoblastic disease and certain non-trophoblastic neoplasms. • This test provides a presumptive diagnosis of pregnancy. Pregnancy diagnosis must be confirmed by a physician based on the evaluation of all clinical and laboratory findings. • Alcohol may interfere with the test result. It is not advisable to perform the test after consuming alcoholic beverages. • People with color vision deficiencies such as color blindness or difficulty distinguishing colors may misinterpret the result. Storage The test must be stored at a temperature between 2 and 30 °C, inside the sealed package and within the shelf life. Do not freeze. Shelf life of intact packaging: 36 months. Package contents - HCG pregnancy test. - Desiccant sachet. - Instruction leaflet.
LIVSANE PREGNANCY TEST Description The HCG pregnancy test is a self-diagnostic immunoassay designed for the rapid, visual, and qualitative detection of human chorionic gonadotropin (HCG) in urine samples to be used as an aid in the early diagnosis of pregnancy. Chromatographic immunoassay for the rapid qualitative detection of HCG in urine. The membrane is pre-coated with anti-alpha HCG capture antibodies in the test line area and goat anti-mouse antibodies in the control line area. During the test, the urine sample reacts with the colored conjugate (colloidal gold conjugate and mouse monoclonal anti-beta HCG antibodies) pre-dried on the test kit. The mixture then migrates upward along the membrane by capillary action reacting chromatographically with the colored conjugate. Positive samples react with the specific anti-HCG antibody colored conjugate forming a pink line in the test line area of the membrane. If no pink line appears in this area, the test result is negative. Regardless of the presence of HCG, as the mixture continues to migrate along the membrane towards the immobilized goat anti-mouse antibody, a pink line will always appear in the control line area. The presence of this pink line serves to: 1. verify that the added volume is sufficient; 2. confirm that the obtained flow is adequate; 3. act as a reagent control. Instructions for Use SAMPLE COLLECTION 1. Collect a fresh urine sample using a clean, dry, single-use container. 2. First morning urine samples generally contain the highest concentration of HCG for early pregnancy diagnosis. However, any urine sample can be used for the test. 3. Samples can be stored at room temperature for eight hours. If the test cannot be performed immediately, samples can be stored at 2-8 °C for 48 hours or at -20 °C for a maximum of 18 months. Do not freeze and thaw the sample more than once. 4. Bring the urine sample to room temperature before performing the test. TEST PROCEDURE Before performing the test, allow the kit, urine sample, and/or control devices to stabilize at room temperature (1-30 °C). Do not open the package until ready to perform the test. First morning urine samples generally contain the highest concentration of HCG for early pregnancy diagnosis. However, any urine sample can be used for the test. 1. Remove the kit from the sealed package and use it as soon as possible. 2. Remove the cap to expose the absorbent tip. 3. Hold the test by the handle with the absorbent tip facing downward. Urinate directly onto the absorbent tip until it is completely wet (at least 5 seconds). Alternatively, collect a urine sample in a clean, dry container with enough urine to fully immerse the absorbent tip for at least 5 seconds. NOTE: Be careful not to urinate on the result window. 4. Replace the cap and place the stick on a flat surface with the reading window facing upward. 5. Wait for the pink lines to appear. Read the result within 5 minutes. Do not read the result after 5 minutes. Interpretation of Results POSITIVE (PREGNANT): Two distinct pink lines appear, one in the test area (T) and one in the control area (C). NOTE: The intensity of the pink color in the test area (T) may vary depending on the concentration of HCG in the sample. Therefore, any shade of pink in the test region (T) should be considered a positive result. NEGATIVE (NOT PREGNANT): Only one pink line appears in the control area (C). No visible pink line appears in the test area (T). INVALID: The control line does not appear. NOTE: Insufficient sample volume or incorrect test execution are the most likely causes of the absence of the control line. Review the procedure and repeat the test with a new kit. If the problem persists, contact your local distributor. Warnings - Read the instructions carefully before performing the test. - Pay attention to the position of the C and T lines. - Do not use the product beyond the expiration date indicated on the label. - The test kit must be stored inside the sealed package until use. Do not use the product if the package is damaged or opened. - Do not reuse the test kit. Dispose of the product after a single use. - Do not touch the membrane inside the reading windows. - Do not ingest the desiccant. Limitations • Although it is not necessary to perform the test with first morning urine samples, excessive fluid intake before the test should be avoided. Overly diluted urine may give a false negative result. • The contents of this kit are intended exclusively for the qualitative detection of HCG in urine. • A sample with a low HCG level may show color changes over time. If pregnancy is suspected despite a negative result, collect another sample and repeat the test after 48-72 hours. • Fertility drugs containing HCG may produce misleading results (these drugs are usually administered by injection and testing too soon after administration may yield false positive results). • Other fertility treatments, painkillers, and hormonal contraceptives should not affect the result. • HCG may continue to be detectable for varying periods from several days to weeks after childbirth, miscarriage, or HCG injections. • Ectopic pregnancies, ovarian cysts, menopause, and some very rare diseases may cause erroneous results. • Although pregnancy is the most likely cause of HCG in serum and urine, elevated HCG concentrations not associated with pregnancy have been reported in some patients with trophoblastic disease and certain non-trophoblastic neoplasms. • This test provides a presumptive diagnosis of pregnancy. Pregnancy diagnosis must be confirmed by a physician based on the evaluation of all clinical and laboratory findings. • Alcohol may interfere with the test result. It is not advisable to perform the test after consuming alcoholic beverages. • People with color vision deficiencies such as color blindness or difficulty distinguishing colors may misinterpret the result. Storage The test must be stored at a temperature between 2 and 30 °C, inside the sealed package and within the shelf life. Do not freeze. Shelf life of intact packaging: 36 months. Package contents - HCG pregnancy test. - Desiccant sachet. - Instruction leaflet.
Information about the price and availability of this product is displayed by LIKI24, not to be offered for sale, but to allow you as a customer to decide which mandate service you wish to purchase. LIKI24 is not a seller/reseller of the displayed product. Only authorized pharmacies are the sellers of the respective products. You are given the opportunity to mandate the Delivery Agent to purchase this product, on your behalf, at the price publicly presented by authorised seller.
LIKI24 does not list this product for sale, distribution, delivery under no title, import, export. LIKI24 does not carry out any operation on the circulation of medicines, including distance selling through information society services.